x
Send Your Inquiry Today
Quick Quote

How to Install Mounted Bearing Units: Step-by-Step Guide

Quick Answer: Installing a mounted bearing unit is a controlled sequence: isolate the machine, inspect and measure the shaft, confirm the housing style and locking method, align the housing with the shaft, then tighten fasteners and locking elements to the exact model-specific torque. Rotate the shaft by hand before guards are refitted, and never mix torque values between locking styles or unit series.


Mounted bearing units are convenient, but they are not fit-and-forget parts. Many installation problems begin before the first bolt is tightened: a worn shaft, a distorted housing seat, the wrong locking collar, or a torque value borrowed from another unit. This guide explains how to install a mounted bearing unit in a professional sequence for pillow block, flanged, and take-up units with insert bearings, with the checks that keep the installation safe and repeatable.

Scope, Standards, and What Professional Installation Covers

A mounted bearing unit is a ready-to-mount assembly that combines an insert bearing with a housing. The insert bearing carries the shaft; the housing supports and locates it. The common housing styles are pillow (plummer) block, flanged, and take-up. The same guide applies to cast and pressed steel housings only when the unit is designed for that housing and the manufacturer’s instructions cover it.

Two ISO standards frame the hardware. ISO 3228:2013 covers outline dimensions and tolerances for cast and pressed housings for insert bearings; the fourth edition was published in February 2013 and was reaffirmed in 2025. ISO 9628:2019 covers insert bearings and eccentric locking collars, including dimensions, geometry, tolerances, and radial internal clearance; the third edition was published in September 2019 and was reaffirmed in 2025. The responsible committee is ISO/TC 4/SC 6, Insert bearings.

These standards define interchangeability and geometry. They are not product certification, approval, or a performance guarantee. The unit nameplate, model marking, current DUHUI catalog, and OEM requirements take precedence over generic values in this guide. If an OEM specifies a stricter shaft tolerance, alignment limit, lubricant, or torque, follow the OEM.

This guide covers standard mounted bearing unit installation. Special custom housings, non-standard shafts, and applications outside the catalog range need verification with the unit manufacturer or OEM.

Safety and Lockout/Tagout Before Work Starts

Before any maintenance or installation, isolate every energy source. Release or restrain stored or residual energy, then verify that the equipment is isolated before work begins. In US industrial maintenance, the governing reference is OSHA 29 CFR 1910.147, control of hazardous energy (lockout/tagout). Outside the United States, use the local equivalent regulation.

Before restart, remove tools and non-essential items, confirm guards and components are restored, make sure all personnel are clear, and notify affected workers. Do not energize the machine until the installation checks in this guide are complete.

This section applies to industrial maintenance in the United States. Local workplace safety rules can be stricter and must be checked.

Identify the Unit, Housing Style, and Locking Method Before Installation

Confirm the housing style first: pillow/plummer block, flanged, or take-up. Then confirm the locking method on the insert bearing: setscrew inner ring, eccentric locking collar, or adapter sleeve. Record the model, shaft size, and locking style before starting. The procedure and torque value follow the locking method, not the housing shape alone.

Do not mix installation procedures or torque values between locking styles. A common error is applying the eccentric-collar rule, tighten in the direction of shaft rotation, to an ordinary double-setscrew inner ring. That rule belongs to eccentric collars. For two-setscrew units in the UC series, the two setscrews are spaced 120° apart. For eccentric collars, hand-tighten in the main shaft rotation direction, then complete locking with a hook spanner or drift. If the locking style is unclear, stop and verify the unit against the DUHUI catalog or nameplate.

How to Install a Mounted Bearing Unit: Step-by-Step Sequence

  1. Prepare and inspect the shaft, housing mounting surface, and bearing unit.
  2. Install the lubrication nipple where applicable, then slide the unit onto the shaft.
  3. Fix the housing with the correct fasteners and flat washers. Keep initial alignment loose enough to align with the shaft.
  4. Align the housing or housings using the shaft, and set axial position before locking the inner ring.
  5. Tighten housing/foot fasteners and locking elements to the model-specific torque.
  6. Rotate the shaft by hand several turns to confirm free rotation before fitting end caps or guards.
  7. Complete the trial run and acceptance checks before handover.

For a double-setscrew UC-series unit, the sequence is: prepare the shaft; install the lubrication nipple and slide the unit onto the shaft; fix the housing with fasteners and washers; then tighten the inner-ring setscrews progressively and alternately to torque. For a housing-alignment installation, use the shaft to align the housings first, set axial position, and only then lock the inner ring or locking sleeve.

Tools, Fasteners, and Documentation Checklist

  • Calibrated torque wrench and correct sockets or drivers for housing bolts and locking screws.
  • Flat washers matching the housing-foot fastener diameter.
  • Hook spanner or drift for eccentric locking collars where specified.
  • Clean measuring and deburring tools for shaft preparation.
  • Current model-specific instructions and a torque table for the exact unit.

Before fitting, confirm that the setscrew ends do not protrude into the bearing bore. For UC-series units, use flat washers matching the bolt diameter under housing-unit foot fasteners. Check setscrew protrusion before mounting. Document the model, locking style, applied torque, lubrication status, and installation date. Fastener grade and washer type must match the manufacturer’s requirement. Impact tools are not a substitute for controlled torque tightening; use only manufacturer-approved methods.

Pre-Installation Inspection

Inspect the shaft, housing, mounting surface, and bearing unit before assembly. Reject or correct any unit with damaged seals, corrosion, contamination, or rough rotation. Verify whether the unit is factory pre-lubricated or needs initial grease according to the manufacturer. Check that the shaft and housing are compatible with the selected unit.

Shaft Condition and Shaft Diameter Tolerance

The shaft must be clean, burr-free, straight, and of the correct diameter. Do not install a bearing on a worn shaft section. Measure the shaft diameter before installation and compare it with the applicable tolerance. High shaft hardness can reduce the effectiveness of setscrew locking. For UC-series units, hardness above HRC 45 can reduce locking effectiveness. For heavy loads, high speed, or vertical shaft applications, consult the equipment manufacturer or bearing manufacturer.

For a general-duty UC-series unit, the shaft tolerance table is:

Shaft diameterTolerance
12-18 mmNominal to -11 μm
19-30 mmNominal to -13 μm
31-50 mmNominal to -16 μm
51-80 mmNominal to -19 μm
81-90 mmNominal to -22 μm

These values apply to general-duty applications. Worn or undersized shafts must be repaired or replaced; do not compensate by over-tightening the setscrews.

Housing, Mounting Surface, and Fastener Check

The mounting surface must be clean and allow the housing to seat fully. Use the correct housing fasteners and flat washers. Check that the housing is not distorted by uneven or over-tightened fasteners. For pressed steel housings, final bolt tightening can remove later misalignment compensation unless a rubber seat ring is used. Certain vertical housed units with rubber seat rings may retain some misalignment capability.

Bearing Unit Inspection and Pre-Lubrication Status

Check that the unit rotates freely before installation and that the seals are intact. Confirm the setscrew ends do not protrude into the bore. During shaft fitting, do not twist the bearing, strike the slinger, or subject the unit to impact. Manufacturer guidance for UC-series units generally states that the units are pre-lubricated at delivery; confirm the pre-lubrication status of the actual DUHUI unit from the catalog or nameplate. Pre-lubricated status affects commissioning and the lubrication schedule. Special-purpose or washed-down units may require different initial lubrication.

Shaft Preparation and Correct Fit

Clean and deburr the shaft; remove rust, paint, and raised marks. Measure diameter and roundness at the bearing seat. Slide the unit onto the shaft without forcing or twisting. If the shaft-to-inner-ring clearance is small, optional shallow flats can be ground at the setscrew contact points to aid later disassembly; the depth guidance is given in the next subsection. Flats do not replace correct shaft diameter or correct setscrew torque.

Do not heat, weld, or flame-cut the bearing unit or its components. Do not use flats as a substitute for correct shaft diameter or correct setscrew torque. Do not grind flats on hardened or critical shafts without engineering approval.

Mount the Housing and Set Initial Alignment

Install the lubrication nipple where applicable before sliding the unit onto the shaft. Slide the unit onto the shaft squarely. Position the housing on its mounting surface and install fasteners with flat washers. Snug the housing fasteners, but align the housing or housings using the shaft before final tightening. Set axial position before locking the inner ring or adapter sleeve. Final-tighten housing fasteners only after alignment is established.

For a UC-series unit, lubrication nipple installation and shaft fitting come before housing fixation. For a two-housing arrangement, use the shaft to carefully align two housings before tightening the housing bolts to the specified torque. In a two-bearing shaft arrangement, align both housings before locking either inner ring. If the shaft cannot be used for alignment, use the manufacturer-approved alignment method.

Alignment Limits and Misalignment Correction

The spherical outer ring can compensate limited static installation misalignment. It cannot correct a bent shaft, severe misalignment, or continuous dynamic deflection. Maximum permissible misalignment depends on whether the housing is relubricated through the housing. Manufacturer maintenance-handbook guidance gives a maximum of 2° where relubrication through the housing is required, and some designs may allow up to 5° where relubrication through the housing is not required. These values apply only to designs and configurations covered by the manufacturer’s instructions.

Pressed steel housings generally cannot compensate misalignment after the bolts are fully tightened unless a rubber seat ring is used. Do not use the self-aligning capability to hide shaft bending or poor mounting-surface alignment.

Torque Reference: Housing Bolts, Setscrews, and Collar Screws

Use only the torque value tied to the exact brand, model, thread size, and locking style. Never mix torque tables from different manufacturers or locking styles. When DUHUI provides a model-specific torque, use the DUHUI value. If no DUHUI torque table is available for the unit, obtain the value from the current catalog or manufacturer before tightening. Torque values differ because of thread size, bearing series, housing design, and locking mechanism.

Housing and Foot Bolt Torque

Use the manufacturer’s housing or foot-bolt torque for the actual fastener and housing. Use flat washers under foot fasteners. Do not substitute one manufacturer’s installation bolt torque for another unit’s housing torque.

For a UC-series unit, one manufacturer’s metric foot-bolt torque table gives:

Metric boltTorque range
M1012-21 N·m
M1221-37 N·m
M1434-60 N·m
M1653-93 N·m
M20104-186 N·m
M22143-256 N·m

A manufacturer maintenance-handbook table for these structures gives the following installation bolt or nut torque:

Metric bolt or nutTorque
M69 N·m
M822 N·m
M1045 N·m
M1280 N·m
M16200 N·m
M20385 N·m
M24665 N·m

These values apply only to the structures and fastener sizes covered by the referenced table. Do not use one table as a direct replacement for another unit’s foot-bolt torque.

Setscrew Torque by Series and Model

Tighten setscrews progressively and alternately where two screws are used. Use the exact model or thread torque from the manufacturer. For two-setscrew units, the screws are spaced 120° apart. For TF/TR setscrew units, select torque by shaft diameter. For UC-series units, select torque by setscrew thread size or by unit model, depending on the table the manufacturer publishes.

For a UC-series unit using a thread-size-based manufacturer table:

Setscrew threadTorque
M6 x 0.754.0 N·m
M8 x 18.5 N·m
M10 x 1.2517.5 N·m
M12 x 1.528.0 N·m

For a UC-series unit using a model-range manufacturer table:

Unit modelTorque
UC201-UC2053.9 N·m
UC2064.9 N·m
UC2075.8 N·m
UC208-UC2107.8 N·m
UC21216.6 N·m
UC217-UC21829.4 N·m

For TF/TR setscrew units, a shaft-diameter-based manufacturer table gives:

Shaft diameterTorque
Up to 25 mm4 N·m
25-30 mm6.5 N·m
30-65 mm16.5 N·m
65-100 mm28.5 N·m

Values are model- and thread-specific. Shaft hardness above HRC 45 may reduce locking effectiveness; consult the manufacturer for alternative locking.

Eccentric Collar Setscrew Torque

Use the eccentric-collar setscrew torque for the exact UEL/AEL model. Do not use inner-ring setscrew torque for eccentric collar screws unless the manufacturer specifies it. Tighten the collar in the main shaft rotation direction before final setscrew torque.

For UEL/AEL eccentric-collar units, a manufacturer setscrew torque table gives:

Unit modelTorque
UEL204-UEL205 / AEL201-AEL2057.8 N·m
UEL206 / AEL2069.8 N·m
UEL208-UEL21015.6 N·m
UEL212-UEL21529.4 N·m

This applies to UEL/AEL eccentric locking collar units. Do not apply this table to ordinary double-setscrew inner rings.

Locking the Inner Ring: Setscrew Method

Complete housing alignment and axial positioning before locking the inner ring. On two-setscrew units, the two setscrews are spaced 120° apart to create a more even three-point clamp; tighten them progressively and alternately rather than fully tightening one screw before the other. Use the model-specific torque table and do not estimate by feel. Confirm the shaft still rotates freely after locking. If the shaft is harder than HRC 45 or worn, locking effectiveness may be reduced.

Torque wrench engaging a setscrew on the extended inner ring of an insert bearing on a shaft

Shaft Flats for Setscrew Contact

Optional flats can be ground at the setscrew contact points when the shaft-to-inner-ring clearance is small. Manufacturer installation guidance for comparable units gives a depth of about 0.2-0.5 mm (0.01-0.02 in) at those contact points. Flats aid later disassembly but do not replace correct shaft diameter or correct setscrew torque. Deburr the flats and clean the shaft before final assembly. Use them only when the shaft design and application allow local material removal, and do not grind flats on hardened or critical shafts without engineering approval.

Shallow ground flats on a steel shaft at the setscrew contact area beside a micrometer

Locking the Inner Ring: Eccentric Collar Method

Fit the eccentric locking collar onto the inner-ring extension. Hand-tighten the collar in the main shaft rotation direction. Use a hook spanner or drift to complete collar locking. Tighten the collar setscrew to the model-specific torque. Verify free rotation after locking. This procedure applies only to eccentric locking collar designs. Do not apply the rotation-direction tightening rule to standard double-setscrew inner rings.

Locking the Inner Ring: Adapter Sleeve Method

Position the adapter sleeve on the shaft before final bearing placement. Remove the locknut and tab washer as required by the procedure. Install the adapter sleeve with its threaded end facing outward. After the inner ring, sleeve, and shaft are in contact, rotate the locknut further by the specified amount or to the specified torque. Prevent the adapter sleeve from rotating with the locknut during tightening. Lock the tab washer into the locknut slot after final tightening. For adapter-sleeve units, about 70° further rotation after contact is given, or the model-specific torque value, and one tab of the tab washer is bent into the locknut slot. Model-specific locknut torque must be verified from the DUHUI catalog or manufacturer.

Lubrication, Temperature Limits, and Prohibited Practices

Confirm whether the unit is factory pre-lubricated before adding grease. Relubricate through the lubrication nipple until old grease is expelled, where the manufacturer permits. Adjust lubrication frequency for speed, temperature, contamination, washdown, and OEM requirements. Do not weld any part of the mounted bearing unit. Do not use open flame to heat mounted bearing unit components. Respect the manufacturer’s maximum operating temperature.

For a UC-series unit, general relubrication guidance is: indoor use usually no relubrication; outdoor use 2-3 times per year; severe outdoor exposure monthly; high contamination or frequent washdown weekly. The maximum operating temperature given in manufacturer guidance for UC-series units is 121°C (250°F). These frequencies are general UC-series guidance and must be adjusted to actual service conditions. Special greases, food-grade requirements, or high-temperature units may have different limits.

Trial Run, Acceptance Checks, and Handover

Rotate the shaft by hand several turns after locking and before fitting end caps or guards. Confirm the shaft rotates freely without binding or abnormal friction. Check that the housing is fully seated and fasteners are tightened to specification. Check that setscrews and collar screws are tightened to the correct torque. Confirm lubrication nipple accessibility. Restore guards and covers; remove tools; confirm personnel are clear; notify affected workers before restart. The OSHA restart checks require removal of tools and non-essential items, complete components, personnel safety, and notification of affected workers. Complete all checks before energizing or restarting. If binding or abnormal friction is found, stop and investigate before running.

Maintenance and Reinstallation Notes After Commissioning

Record the installed model, locking style, torque values, and lubrication date. Follow the manufacturer’s lubrication schedule and reorder the same locking style. Use the correct torque table again after any reinstallation. Do not reuse damaged setscrews, collars, tab washers, or adapter sleeves. For DUHUI replacements, verify the current catalog torque and clearance data; if the value is not stated, obtain it from the manufacturer before installation.

This applies to routine maintenance and like-for-like replacement. Modified shafts, new duty conditions, or a different bearing series require re-verification.

Conclusion

Professional mounted bearing unit installation is a sequence of small, verifiable decisions: isolate the machine, measure the shaft, identify the locking method, align the housings with the shaft, and tighten only with the torque value that belongs to the exact unit. The self-aligning housing can absorb limited static error, not a bent shaft or a distorted mounting surface. Before handover, rotate the shaft by hand, confirm free rotation, restore guards, and record the model, torque, and lubrication details. If the unit marking, locking style, or torque value is unclear, stop and verify it against the current DUHUI catalog or nameplate.

FAQs

Q1: What torque should I use for mounted bearing unit setscrews?
A: Use the value for the exact unit series and thread or shaft size. For a UC-series unit using the thread-size table, M6 x 0.75 is 4.0 N·m, M8 x 1 is 8.5 N·m, M10 x 1.25 is 17.5 N·m, and M12 x 1.5 is 28.0 N·m. For a UC-series unit using the model-range table, UC201-UC205 is 3.9 N·m and UC217-UC218 is 29.4 N·m. For TF/TR units, torque is 4 N·m up to 25 mm, 6.5 N·m for 25-30 mm, 16.5 N·m for 30-65 mm, and 28.5 N·m for 65-100 mm. Do not substitute one table for another.

Q2: Should I tighten the two setscrews fully one at a time?
A: No. Tighten them progressively and alternately so the inner ring seats evenly on the shaft. On two-setscrew units, the two screws are spaced 120° apart to create a more even three-point clamp. Finish both screws to the model-specific torque, then rotate the shaft by hand to confirm free rotation.

Q3: Which direction should an eccentric locking collar be tightened?
A: Hand-tighten the collar in the main shaft rotation direction, then complete locking with a hook spanner or drift and tighten the collar setscrew to the model-specific torque. This rotation-direction rule applies to eccentric collars, not to ordinary double-setscrew inner rings.

Q4: Can I install a mounted bearing unit on a worn shaft?
A: No. The shaft must be clean, burr-free, straight, and of the correct diameter. A worn section reduces fit and locking effectiveness. Measure the shaft and compare it with the applicable tolerance. If the shaft is undersized or worn, repair or replace it rather than over-tightening the setscrews.

Q5: How much misalignment can a mounted bearing unit accept?
A: The spherical outer ring can compensate limited static installation misalignment. Manufacturer maintenance-handbook guidance gives a maximum of 2° where relubrication through the housing is required, and some designs may allow up to 5° where relubrication through the housing is not required. These limits do not correct a bent shaft, severe misalignment, or continuous dynamic deflection.

Q6: How often should a mounted bearing unit be relubricated?
A: Follow the unit manufacturer and OEM schedule. For a UC-series unit, general guidance is no relubrication for indoor use, 2-3 times per year outdoors, monthly for severe outdoor exposure, and weekly for high contamination or frequent washdown. Adjust for speed, temperature, contamination, and actual service conditions.

Q7: Can a mounted bearing unit be welded or heated with a flame?
A: No. Do not weld any part of the mounted bearing unit, and do not use open flame to heat its components. Respect the maximum operating temperature. For UC-series units, manufacturer guidance gives a maximum of 121°C (250°F). Use the temperature limit for the actual unit and lubricant.

Q8: What should I check before restarting the machine?
A: Confirm the shaft rotates freely by hand, the housing is fully seated, fasteners and locking screws are at the correct torque, the lubrication nipple is accessible, and guards and covers are restored. Remove tools and non-essential items, make sure personnel are clear, and notify affected workers before restart. If binding or abnormal friction is present, stop and investigate.

Scroll to Top